LI-8100A Automated Soil CO2 Flux System
The LI-8100A Automated Soil CO2 Flux System provides researchers sophisticated flux monitoring instrumentation in a dedicated system that is modular and easy to use.
- Designed to minimize changes to the soil and environment that can affect the natural soil CO2 production and diffusion processes.
- New patent-pending pressure vent design minimizes pressure pulses at chamber closing and allows pressure inside the chamber to track the ambient pressure even under windy conditions.
- Both survey and long-term chambers close automatically, eliminating variations caused by manual chamber placement.
- CO2 flux is calculated at the CO2 concentration of the surrounding ambient air. This minimizes effects resulting from the necessary increase in chamber CO2 concentration during a measurement.
- Chamber geometry facilitates mixing without using fans, thus eliminating potential for chamber pressure perturbation.
- Data analysis software is a powerful tool for viewing and quality control of data.
- Measure in high CO2 environments up to 20'000 ppm.
- Wireless communications and LAN connectivity enabled.
Survey Chambers
The pneumatic bellows system raises the chamber between repetitions to allow for equilibration with ambient CO2 and H2O concentrations, before gently lowering again to perform another repetition. As a result, erroneous flux rates, induced by mechanical soil disturbance, are greatly reduced.
8100-102 Survey Chamber
10 cm diameter chamber.
8100-103 Survey Chamber
20 cm diameter chamber.
LI-8150 Multiplexer
The LI-8150 Multiplexer greatly expands the capability of the LI-8100A and provides a simple solution that satisfies both temporal and spatial resolution requirements for monitoring CO2 flux.
- Connect up to 16 Long-Term Chambers
- 30 m diameter coverage
- Easy connection to the LI-8100A Control Unit
- Single gas analyzer in the LI-8100A prevents measurement bias
- Conduct vertical atmospheric CO2 profile measurements
Long-Term Chambers
Long-term chambers to make unattended measurements of diel and seasonal soil CO2 flux patterns. These chambers attach to either the LI-8100A (direct connection), or to the LI-8150 Multiplexer.
- requires choice of 2 m or 15 m cable/hose assembly
- Auxiliary Sensor inputs are integrated into chamber for use in a multiplexed system
8100-104 Single Long-Term Chamber
20 cm diameter chamber.
8100-104C Single Long-Term Chamber
20 cm diameter chamber with transparent cover.
Detailed information about the LI-8100A ...
Detailed information about the LI-8150 ...
Workshops